Renesas Electronics /R7FA2A1AB /DAC8 /DAM

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as DAM

7 43 0 0 00 0 0 0 0 0 0 0 0 (0)DAMD0 0 (0)DAMD1 0 (Reserved)Reserved 0 (Reserved)Reserved 0 (0)DACE0 0 (0)DACE1 0 (Reserved)Reserved 0 (Reserved)Reserved

DACE1=0, DAMD1=0, DAMD0=0, DACE0=0

Description

D/A Converter Mode Register

Fields

DAMD0

D/A operation mode select 0

0 (0): Channel 0 for normal operation mode

1 (1): Channel 0 for real-time output mode(event link)

DAMD1

D/A operation mode select 1

0 (0): Channel 1 for normal operation mode

1 (1): Channel 1 for real-time output mode(event link)

Reserved

This bit is read as 0. The write value should be 0.

Reserved

This bit is read as 0. The write value should be 0.

DACE0

D/A operation enable 0

0 (0): D/A conversion disabled for channel 0

1 (1): D/A conversion enabled for channel 0

DACE1

D/A operation enable 1

0 (0): D/A conversion disabled for channel 1

1 (1): D/A conversion enabled for channel 1

Reserved

This bit is read as 0. The write value should be 0.

Reserved

This bit is read as 0. The write value should be 0.

Links

()